ELECTRIC STARTER
STARTER RELAY SWITCH
INSPECTION
Depress the starter switch button with the ignition ON.
The coil is normal if the starter relay switch clicks.
Connect an ohmmeter to the starter relay switch terminals.
Connect a 12 V battery to the switch cable terminals.
The switch is normal if there is continuity.
CLUTCH DIODE
CLUTCH DIODE
REMOVAL
Remove the fuel tank.
Remove the clutch diode from the wire harness.
NORMAL DIRECTION: CONTINUITY REVERSE DIRECTION: NO CONTINUITY
INSPECTION
Check for continuity with an ohmmeter.
Date of Issue: May, 1982 327 © HONDA MOTOR CO., LTD.