V45 CABLE TERMINAL-MOTOR CASE NO CONTINUITY: NORMAL FIELD COIL INSPECTION PIN CASE CABLE TERMINAL-BRUSH WIRE (BLACK) CONTINUITY: NORMAL BRUSH HOLDER NOTCH PIN BRUSH HOLDER SLOT Install the rear cover aligning its slot with the brush holder pin. Install the starter motor in the reverse order of removal. Check for continuity from the cable terminal to the motor case and from the cable terminal to the brush wire. Replace the starter motor if the field coil is not continuous or if it is shorted to the motor case. ASSEMBLY/INSTALLATION Assemble the starter motor. Align the case notch with the brush holder pin. REAR BRACKET 326 ELECTRIC STARTER Date of Issue: January, 1982 © HONDA MOTOR CO., LTD. 20-4