V45
BATTERY/CHARGING SYSTEM
ph.>
SERVICE INFORMATION 18-1
TROUBLESHOOTING 18-2
BATTERY 18-3
CHARGING SYSTEM 18-4
SERVICE INFORMATION
GENERAL
Battery fluid level should be checked regularly. Fill with distilled water when necessary.
Quick charge a battery, only in an emergency. Slow-charging is preferred.
Remove the battery from the motorcycle for charging. If the battery must be charged on the motorcycle, disconnect the battery cables.
WARNING
Do not smoke, and keep flames away front a charging battery. The gas produced by a battery will explode if flames or sparks are brought near.
All charging system components can be tested on the motorcycle.
Alternator removal is in Section 9.
SPECIFICATIONS
Battery Capacity 12V 14AH
Specific gravity 1.280/20°C (68°F)
Charging rate 1.4 amperes maximum
Alternator Capacity 1,000 rpm 5,000 rpm
10.2A min. (No load) 25A min. (No load)
Voltage regulator Transistorized non-adjustable regulator
18
Date of Issue: May, 1982
© HONDA MOTOR CO., LTD.
309 18-1