CRANKCASE
HONDA
V45
6 mm BOLT
Tighten the upper crankcase bolts to the specified torque in a crisscross pattern and in 2-3 steps.
TORQUE: 8 mm: 21-25 N.m
(2.1-2.5 kg-m, 15-18 ft-lb)
6 mm: 10-14 N.m
(1.0-1.4 kg-m, 7-10 ft-lb)
NOTE:
Make sure that the plain washers are under the bolt heads of the three crankcase mounting bolts shown.
8 mm BOLT AND 6 mm BOLT AND
PLAIN WASHERS PLAIN WASHERS MAINSHAFT BEARING HOLDER
Install the mainshaft bearing holder and tighten the screw and bolt.
CRANKCASE BOLT
OUTPUT GEAR CASE
8 mm BOLT AND WASHERS BEARING HOLDER BOLTS
6 mm BOLT 6 mm BOLT 8 mm SOCKET BOLT AND WASHER
Install a new output gear case gasket with one of the same thickness as removed.
NOTE:
If the gasket was not measured during disassembly, refer to page 13-6 for gasket selection procedures.
Early production engines had gaskets that were not marked.
The gasket is crushed 0.05 mm when the output gear case is installed.
Install the output gear case with a new gasket. Install the bolts and sealing washers and then tighten to the specified torque.
TORQUES:
Output gear case
bearing holder bolts: 30-34 Kl.in
(3.0-3.4 kg-m, 22-25 ft-lb) 8 mm bolts/socket bolts: 21-25 N-m
(2.1-2.5 kg-m, 14-18 ft-lb) 6 mm bolts: 10-14 N-m (1.0-1.4 kg-m, 7-10 ft-lb)
Date of Issue: May, 1982
© HONDA MOTOR CO., LTD.
11-6 164