HONDA V45 LUBRICATION Start the engine and check the oil pressure at 5,000 rpm. OIL PRESSURE: 4.5 ± 0.8 kg/cm2 (64 ± 11 psi) at 5,000 rpm (80°C/176°F) Stop the engine. Apply 3-BOND® sealant or equivalent to the pressure switch threads and install. TORQUE: 15-20 N•m (1.5-2.0 kg-m, 11-14 ft-lb) Connect the oil pressure switch wire. Start the engine. Operate the warning indicator switch. Check that the oil pressure warning indicator goes out atter one or two seconds. If the oil pressure warning indicator stays on, stop the engine immediately and determine the cause. 011 PUMP REMOVAL NOTE: The oil pump can be removed with the engine mounted in the frame. Drain the engine oil. Remove the exhaust system. Remove the right side cover. Remove the oil pump driven sprocket by removing the bolt and washer. Remove the water pump assembly (page 6-12). Remove the oil strainer (page 2-4) and the oil pass pipe. Make sure the 0-rings are in good condition.OIL PRESSURE GAUGE 07506-3000000 (Not available in U.S.A.) OIL PRESSURE GAUGE ATTACHMENT 07510-4220100 OIL PUMP DRIVEN SPROCKET OIL PASS PIPE 0-RINGS 19 Date of Issue: May, 1982 © HONDA MOTOR CO., LTD. 2-5